- Contact Person : Ms. Cai Frieda
- Company Name : Changsha Beyond Medical Devices Co., Ltd.
- Tel : 86-731-84451212
- Fax : 86-731-88532408,82560162 Address: Lianfeng Community, Hanpu Town, Yuelu District Zip: 410205 Country/Region: China (Mainland) Province/State: Hunan City: Changsha
- Address : Hunan,Changsha,Lianfeng Community, Hanpu Town, Yuelu District
- Country/Region : China
- Zip : 410205
hospital syringe pump BYZ-810 with CE marked
BYZ-810 hospital syringe pump
Features & Functions:
1.Three working modes: rate mode, time-volume mode, dosage-weight mode.
2.Unique Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
3.Automatically calibration and compatible with any brand syringes.
4.Large LCD screen displays working status.
5.KVO and Bolus functions.
Product name | hospital syringe pump |
Model | BYZ-810 hospital syringe pump |
Flow rate | 50ml syringe:0.1~1500ml/h; 30ml syringe:0.1~900.0ml/h; 20ml syringe:0.1~600.0ml/h; 10ml syringe:0.1~300.0ml/h |
The range of limiting volume | 0~999.9ml |
The range of injected volume | 0~9999.9ml |
Accuracy of flow rate | Within ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.) |
Purge rate | Purge rate of 50ml syringe:1500ml/h; Purge rate of 30ml syringe:900.0ml/h; Purge rate of 20ml syringe:600.0ml/h; Purge rate of 10ml syringe:300.0ml/h |
Alarm and warms | The pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on. |
Injection blocked | Choose in the three kinds of occlusion alarm pressure according to the clinical requirements(High,Medium,Low) |
KVO rate | 1ml/h |
Fuse specification | F1AL/250V ,two fuses(installed inside pump) |
Operating power | AC100~240.0V, 50/60Hz, Power:≤30VA Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours. |
Operating environment | temperature:+5~+40°C, relative humidity:20~90% |
Storing environment | temperature:-30°C~+55, relative humidity:≤95%, ( No condensation state ) |
Atmospheric pressure | 860hPa~1060hPa |
Safety level | Class II with insulated enclosure, internal power supply, BF-type continuous normal running equipment. |
IP grade | IPX1 |
Dimensions | 280(L)×210(W)×130(H)(mm) |
Weight | 2.2kg |
Accessories | Power line,operating manual,warranty card,product certification. |
hospital syringe pump BYZ-810 with CE marked